To help Industrial users meet the requirements for MCERTS Siris Environmental have developed a Flow Measurement Tank which encapsulates a range of flow rates within the scope of BS3680. Using an Interchangeable Plate the tank can be set to accurately measure flows up-to a given maximum. In the event of any future increase or decrease in flow measurement volume, perhaps due to changes in production, then the tank and flow meter can be set-up with a different plate and re-programmed.
Features of the Interchange Tank
• Designed to BS3680 to Specifically meet MCERTS compliance
• Interchangeable V or Rectangular Plate
• Laser cut and correctly machined plate
• Stainless Steel or GRP/PVC
• Flow meter fully set-up, programmed & calibrated
• Ultra-Sonic Sensor Sun Shade fitted as standard
• Optional Calibration Target Plate
• Robust Design of both tank and bridge Bracket
• Delivered to Site “Ready To Use” just requires pipe & power connections